TCX® (I) 331 150/250 (300) V

Products

TCX® ( I ) 331 2P0.75

Nexans ref. 10171241 - Country ref. 1042181

  • Packaging: Cut to length (m)
  • Number of pairs: 2
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 12.5 mm
  • Maximum outer diameter: 14.5 mm
  • Approximate weight: 196 kg/km

 

TCX® ( I ) 331 4P0.75

Nexans ref. 10215155 - Country ref. 1042182

  • Packaging: Cut to length (m)
  • Number of pairs: 4
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 14.5 mm
  • Maximum outer diameter: 18.0 mm
  • Approximate weight: 294 kg/km

 

TCX® ( I ) 331 7P0.75

Nexans ref. 10200301 - Country ref. 1042183

  • Packaging: Cut to length (m)
  • Number of pairs: 7
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 17.5 mm
  • Maximum outer diameter: 21.5 mm
  • Approximate weight: 430 kg/km

 

TCX® ( I ) 331 10P0.75

Nexans ref. 25405383

  • Packaging: Cut to length (m)
  • Number of pairs: 10
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 22.0 mm
  • Maximum outer diameter: 25.5 mm
  • Approximate weight: 600 kg/km

 

TCX® ( I ) 331 14P0.75

Nexans ref. 10199548

  • Packaging: Cut to length (m)
  • Number of pairs: 14
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 24.0 mm
  • Maximum outer diameter: 28.8 mm
  • Approximate weight: 816 kg/km

 

TCX® ( I ) 331 19P0.75

Nexans ref. 25405337

  • Packaging: Cut to length (m)
  • Number of pairs: 19
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 26.5 mm
  • Maximum outer diameter: 29.5 mm
  • Approximate weight: 960 kg/km

 

TCX® ( I ) 331 24P0.75

Nexans ref. 25405336

  • Packaging: Cut to length (m)
  • Number of pairs: 24
  • Number of triples: -
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 31.5 mm
  • Maximum outer diameter: 36.0 mm
  • Approximate weight: 1208 kg/km

 

TCX® ( I ) 331 2T0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 2
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 13.5 mm
  • Maximum outer diameter: 15.5 mm
  • Approximate weight: 250 kg/km

 

TCX® ( I ) 331 4T0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 4
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 16.5 mm
  • Maximum outer diameter: 18.5 mm
  • Approximate weight: 360 kg/km

 

TCX® ( I ) 331 7T0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 7
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 19.5 mm
  • Maximum outer diameter: 22.5 mm
  • Approximate weight: 530 kg/km

 

TCX® ( I ) 331 10T0.75

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 10
  • Conductor cross-section: 0.75 mm²
  • Minimum outer diameter: 25.5 mm
  • Maximum outer diameter: 28.5 mm
  • Approximate weight: 750 kg/km

 

TCX® ( I ) 331 2P1.5

Nexans ref. 10280538

  • Packaging: Cut to length (m)
  • Number of pairs: 2
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 15.0 mm
  • Maximum outer diameter: 17.0 mm
  • Approximate weight: 279 kg/km

 

TCX® ( I ) 331 4P1.5

Nexans ref. 25405382

  • Packaging: Cut to length (m)
  • Number of pairs: 4
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 17.5 mm
  • Maximum outer diameter: 20.0 mm
  • Approximate weight: 417 kg/km

 

TCX® ( I ) 331 7P1.5

Nexans ref. 25405334

  • Packaging: Cut to length (m)
  • Number of pairs: 7
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 21.0 mm
  • Maximum outer diameter: 23.5 mm
  • Approximate weight: 630 kg/km

 

TCX® ( I ) 331 10P1.5

Nexans ref. 25405384

  • Packaging: Cut to length (m)
  • Number of pairs: 10
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 26.0 mm
  • Maximum outer diameter: 28.0 mm
  • Approximate weight: 881 kg/km

 

TCX® ( I ) 331 14P1.5

Nexans ref. 25405385

  • Packaging: Cut to length (m)
  • Number of pairs: 14
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 28.5 mm
  • Maximum outer diameter: 31.5 mm
  • Approximate weight: 1129 kg/km

 

TCX® ( I ) 331 19P1.5

Nexans ref. 25405386

  • Packaging: Cut to length (m)
  • Number of pairs: 19
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 32.0 mm
  • Maximum outer diameter: 36.0 mm
  • Approximate weight: 1453 kg/km

 

TCX® ( I ) 331 24P1.5

Nexans ref. 25405387

  • Packaging: Cut to length (m)
  • Number of pairs: 24
  • Number of triples: -
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 38.5 mm
  • Maximum outer diameter: 41.0 mm
  • Approximate weight: 1839 kg/km

 

TCX® ( I ) 331 2T1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 2
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 16.5 mm
  • Maximum outer diameter: 19.0 mm
  • Approximate weight: 410 kg/km

 

TCX® ( I ) 331 4T1.5

Nexans ref.

  • Packaging: Cut to length (m)
  • Number of pairs: -
  • Number of triples: 4
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 19.5 mm
  • Maximum outer diameter: 22.5 mm
  • Approximate weight: 540 kg/km

 

Description

Description

Standards

  • Installation
    IEC 60092-350; IEC 60092-360; IEC 60092-376
  • Test
    IEC 60331-1 or 2; IEC 60331; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
  • International
    IEC 60298

Application

TCX® (I) 331  150/250 V fire resistant armoured individually screened twisted pair cables maintain circuit integrity in case of fire by meeting performances requirements from the IEC 60331 series for 90 minutes. These telecommunication and instrumentation cables provide strong protection aganist cross-talk in both low and high frequency runs, making them suitable for highly polluted electromagnetic surroundings. TCX®(I) 331  cables are used for detection and warning systems where enhanced mechanical protection is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.

Design

  1. Conductor:
    Stranded bare copper
    Class 2
     
  2. Insulation:
    Mica tape + XLPE (cross-linked polyethylene)
    Optional: Special fire resistant HF 90 (halogen-free compound)
    with INFITTM technology
  3. Individual screen:
    Alu/polyester tape with a tinned copper drain wire
  4. Inner covering:
    Lapped polyester tape
  5.  Armouring:
     Bare copper braid
  6. Outer sheath:
    Polyolefin SHF1 (SHF2 on request)
    Colour: orange

 

Marking

I NEXANS I TCX (I) 331 150/250 V  "n" x 2 or 3 x "s" mm²  90°C IEC 60092-376 IEC 60332-3-22 Cat. A  IEC 60331-1/2 "ww/yy" * CE *  TCIF + metric marking

 

 

 

Core identification

Core 1: white
Core 2: blue
Core 3: red
Double identification: core and pair.

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
IEC 60754-1
Sheath colour
Orange

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
150 / 250 (300) V

Usage characteristics

Usage characteristics

Fire retardant
EN IEC 60332-3-22 (cat A)
Fire resistant
IEC 60331-21, IEC 60331-1 or 2
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Electro magnetic interference resistance
Yes
Max. conductor temperature in service
90 °C
Operating temperature, range
-30 ... 80 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close